The formula to calculate the Slip (s) is:
\[ s = \frac{N_{s} - N_{m}}{N_{s}} \]
Slip in Induction Motor is the relative speed between the rotating magnetic flux and rotor expressed in terms of per unit synchronous speed. It is a dimensionless quantity.
Let's assume the following values:
Using the formula:
\[ s = \frac{1639.91136509036 - 1502.72848589059}{1639.91136509036} \approx 0.0836526181353778 \]
The Slip is approximately 0.0836526181353778.
Synchronous Speed (Radian per Second) | Slip |
---|---|
1600 | 0.060794696318381 |
1610 | 0.066628269633174 |
1620 | 0.072389823524327 |
1630 | 0.078080683502706 |
1640 | 0.083702142749640 |
1650 | 0.089255463096612 |
1660 | 0.094741875969524 |
1670 | 0.100162583299048 |
1680 | 0.105518758398458 |
1690 | 0.110811546810302 |
1700 | 0.116042067123182 |